Available pack sizes | |
Packsize | Designation |
420 ml cartridge | LGMT 3.0,4 |
0.5 kg can | LGMT 3/0.5 |
1 kg can | LGMT 3/1 |
5 kg can | LGMT 3/5 |
18 kg pail | LGMT 3/18 |
50 kg drum | LGMT 3/50 |
180 kg drum | LGMT 3/180 |
TLMR 101 series 380 ml refill (incl. battery) | LGMT 3/MR380B |
TLMR 201 series 380 ml refill | LGMT 3/MR380 |
Technical data | ||
Designation | LGMT 3/(pack size) | |
DIN 51825 code | K3K-30 | |
NLGI consistency class | 3 | |
Soap type | Lithium | |
Colour | Amber | |
Base oil type | Mineral | |
Operating temperature range | –30 to +120 °C (–20 to +250 °F) |
|
Dropping point DIN ISO 2176 | >180 °C (>355 °F) | |
Base oil viscosity | ||
40 °C, mm²/s 100 °C, mm²/s |
120–130 12 |
|
Penetration DIN ISO 2137 | ||
60 strokes, 10–1 mm 100 000 strokes, 10–1 mm |
220–250 280 max. |
|
Mechanical stability | ||
Roll stability, 50 hrs at 80 °C, 10–1 mm V2F test |
295 max. ‘M’ |
|
Corrosion protection | ||
Emcor: | – standard ISO 11007 – water washout test |
0–0 0–0 |
Water resistance | ||
DIN 51 807/1, 3 hrs at 90 °C | 2 max. | |
Oil separation | ||
DIN 51 817, 7 days at 40 °C, static, % | 1–3 | |
Lubrication ability | ||
R2F, running test B at 120 °C | Pass | |
Copper corrosion | ||
DIN 51 811, 110 °C | 2 max. at 130 °C (265 °F) | |
Rolling bearing grease life | ||
R0F test L50 life at 10 000 r/min., hrs | 1 000 min. at 130 °C (265 °F) |